10.6 QUANTIZE MENU

10. THE SEQUENCER > 10.6 QUANTIZE MENU · PDF p. 45 · OS 1.15A

# 10.6 QUANTIZE MENU

10. THE SEQUENCER
sequencer step.
AND only trigs added to the same sequencer step by generator 1 and 2 are placed on the track.
SUB trigs from generator 1 are placed on the track unless generator 2 adds a trig on the same step
as generator 1.
•	 If you place any trigs in normal sequencer mode, when you switch to Euclidean mode,
these trigs will be distributed according to the settings.
•	 In Euclidean mode, please note that if you press any already placed trigs, they will remain
in regular sequencer mode when you switch Euclidean mode off.
10.4 MICRO TIMING
Here you can add micro timing to a note trig, moving it ahead or behind the beat. Micro timing can be
customized on any of the sequencer steps on both audio and MIDI tracks. In GRID RECORDING mode,
press and hold one or several [TRIG] keys and then press [LEFT]/[RIGHT] to access the pop-up Micro
timing menu that shows the time offset for the chosen sequencer step(s) on the active track. Press [LEFT]/
[RIGHT] to adjust the time offset. To exit the MICRO TIMING menu, release the [TRIG] key(s). The micro
timing settings are stored in the active pattern.
For more information about the parameters on this page, please see “11.2 TRIG PAGE 1” on page 53
10.5 RETRIGS
Retrigs can be customized on any of the sequencer steps on the audio tracks (the retrig function is not
available on the MIDI tracks). In GRID RECORDING mode, press [TRIG PARAMETERS] twice to access the
RETRIG PARAMETERS page. Hold one or several [TRIG] keys and then set the desired retrig options for
the trig(s).
For more information about the parameters on this page, please see “11.3 TRIG PAGE 2” on page 54.
10.6 QUANTIZE MENU
The quantization affects all micro timed and off grid trigs on the sequencers tracks. Press [FUNC] +
[TRIG PARAMETERS] to access this menu. Change settings with DATA ENTRY knob E and H.
TRACK affects all the trigs of the active track in real time. The higher the quantize value, the more the
trigs will be quantized. Press [TRIG 1–16] key to select track to quantize.
PATTERN affects all the trigs of all tracks in the pattern in real time. The higher the quantize value, the
more the trigs will be quantized.
Press [NO] to exit the menu.
10.7 PAGE SETUP MENU
You can set the length and timing of the pattern and the tracks in this menu. The sequencer has up to 128
steps spread over 8 pages with 16 steps each. The PAGE SETUP menu has two modes. In PER PATTERN
mode all tracks share the same length. In PER TRACK mode, each track can have different lengths. Press

Chunks share pages with neighboring sections; text before/after the section heading belongs to the adjacent sections.