10.2.1 NOTE
Trig Note sets the pitch of the note when trigged. When in LIVE RECORDING mode and playing in KEYBOARD mode, the pitch of the [TRIG] keys played will override this setting.
10.2.2 VEL
Trig Velocity sets the velocity of the sequencer’s note trigs.
10.2.3 LEN
Trig Length sets the length of the note trig. In LIVE RECORDING mode, the duration of pressing the [TRIG] keys overrides this general setting. LEN can be set to infinite length
10.2.4 PROB
Trig Probability sets the probability that the trigs on the track plays or not. The probability outcome is re-evaluated every time a trig is set to play. The default setting is 100%, meaning that all the trigs on the track plays every time. (0%–100%)
This parameter changes temporarily to display and control COND (Trig Condition) when you add a conditional lock. COND sets the Trig Condition with which a set of conditional rules can be applied to any trig, using a parameter lock. For more information, please see “9.10.3 TRIG CONDITIONS AND CONDITIONAL LOCKS” on page 44. If you have placed a conditional lock on a trig in the sequencer, the trig condition overrides the Trig Probability setting. For example, if you set PROB to 70% and a FILL trig condition on a trig, that trig will only (and always) play when the Syntakt is in FILL mode. For more information, please see “9.10.3 TRIG CONDITIONS AND CONDITIONAL LOCKS” on page 44.
10.2.5 FLT.T
Filter Trig controls if the filter envelope will be trigged or not.
10.2.6 LFO.T
LFO Trig controls if the LFO will be trigged or not.
10.2.7 PTIM
Portamento Time sets the time for the portamento.
10.2.8 PORT
Portamento turns the portamento on/off.