Knobwerk

← 返回搜索

11.2 TRIG PAGE 1

11. TRACK PARAMETERS > 11.2 TRIG PAGE 1 · PDF 第 57–58 · OS 1.10D

# 11.2 TRIG PAGE 1

11. TRACK PARAMETERS
11. TRACK PARAMETERS
Here follows a description of all of the parameters that are available on the audio tracks PARAMETER
pages. The parameters on the TRIG page are not saved together with the preset, but are instead saved
with the pattern. The track parameters may be locked to other settings on any step of the pattern by first
pressing and holding a [TRIG] key, then changing the parameters’ settings with the DATA ENTRY knobs.
For more information, please see “10.12.1 PARAMETER LOCKS” on page 50.
Please note that MIDI tracks have a different set of parameters on the TRIG, SYN, FLTR, and
AMP pages. For more information, please see “A.2 SYN MACHINES” on page 89.
11.1 EDITING THE TRACK PARAMETERS
There are six PARAMETER pages for the tracks. Press the [PARAMETER] keys to access the tracks
PARAMETER pages. Use the [UP]/[DOWN] keys to access the parameter group's pages. You can also
press a [PARAMETER] key repeatedly to cycle trough the parameter pages in that group. Press and hold a
[PARAMETER] key to see the values for all parameters on that page.
•	 You can always reload a preset from its last saved state. Press [TRK] + [TRIG 1–16] + [NO]
to reload the preset.
•	 You can also randomize the parameter settings on a specific PARAMETER page on an
audio track. Press [PARAMETER] key + [YES] to randomize the relevant parameters on that
page. Every time you press this key combination, the parameters randomize in a new way.
•	 Press [PARAMETER] key + [NO] to reset the PARAMETER page to its last saved state.
11.2 TRIG PAGE 1
Here you set the options for notes that are trigged. This is also where you select trig conditions. Press the
[TRIG PARAMETERS] key to access the menu. Change settings using the DATA ENTRY knobs. These
general settings affect note trigs placed on the sequencer.
NOTE
Trig Note sets the pitch of the note when trigged. When in LIVE RECORDING mode and playing in KEY­
BOARD mode, the pitch of the [TRIG] keys played will override this setting. Press and turn DATA ENTRY
knob A to select only note values that exist in the scale set by KB SCALE. This behavior can be inverted
using the NOTE PARAM setting in the PERSONALIZE menu. For more information, please see “13.7.6
NOTE PARAM” on page 79 and “8.5.2 KEYBOARD SETUP MENU” on page 25.
VEL
Trig Velocity sets the velocity of the sequencer’s note trigs.
LEN
Trig Length sets the length of the note trig. In LIVE RECORDING mode, the duration of pressing the
[TRIG] keys overrides this general setting.
PROB
Trig Probability sets the probability that the trigs on the track plays or not. The probability outcome is
re-evaluated every time a trig is set to play. The default setting is 100%, meaning that all the trigs on the
track plays every time. This parameter can be parameter locked which lets you give separate trigs their
own probability.
LFO.T
LFO Trig controls if the LFO will be trigged or not.

11. TRACK PARAMETERS
FLT.T
Filter Trig controls if the filter envelope will be trigged or not.
FILL
Fill is a separate trig condition that determines if a trig is active (plays) or not depending on if the device
is in FILL mode or not. For more information, please see “10.12.4 FILL MODE” on page 52, and “10.12.3
TRIG CONDITIONS AND CONDITIONAL LOCKS” on page 51.
ON, A trig with FILL set to ON, plays when FILL mode is active.
OFF, A trig with FILL set to OFF plays when FILL mode is not active.
The sequencer needs to be in FILL mode to activate the FILL trig condition. For more
information, please see “10.12.4 FILL MODE” on page 52.
COND
(Trig Condition) when you add a conditional lock, COND sets the Trig Condition with which a set of con­
ditional rules can be applied to any trig, using a conditional parameter lock. For more information, please
see “10.12.3 TRIG CONDITIONS AND CONDITIONAL LOCKS” on page 51.
11.3 TRIG PAGE 2
Here you set the behavior of retrigs that are added to note trigs placed in the sequencer. On this page you
also control the portamento. Change settings using the DATA ENTRY knobs. These general settings all
affect note trigs placed in the sequencer.
Retrigs can be customized on any of the sequencer steps on the audio tracks (the retrig function is not
available on the MIDI tracks). In GRID RECORDING mode, press [TRIG PARAMETERS] twice to access the
RETRIG PARAMETERS page. Hold one or several [TRIG] keys and then set the desired retrig options for
the trig(s). The RETRIG PARAMETERS page shows the retrig actions for the chosen sequencer step(s) on
the active track. The retrig settings are stored in the active pattern.
RTRG
Retrig enables a number of trig repeats on placed trigs. Use DATA ENTRY knob A to turn retrig on/off.
For information on setting retrig locks on specific trigs in the sequencer, please see “10.9 RETRIGS” on
page 48.
VFAD
Velocity Fade sets the velocity curve fade out/fade in of the retrig (-64–64). -64 corresponds to a
complete fade out during the set length, -32 fades out to half the velocity during the set length, 0 equals
a flat velocity curve with no fade, 32 fades into half velocity during the set length and 64 fades in com­
pletely to full velocity during the set length. Please note that the effects of the VFAD setting is also
dependent on the VEL setting on TRIG PAGE 1.
LEN
Length sets the duration of the retrig velocity curve in fractions of, or rational or integer multiples of, a
step (0,125–INF). 1/16 is the nominal length of one step. This setting affects the behavior of the velocity
curve by defining the boundaries of its envelope.
RATE
Rate sets the retrig rate. 1/16 is the nominal retrig rate, one trig per step. 1/32 corresponds to two trigs
per step and so on. To do triplets, for example, set the retrig rate to 1/12 (or 1/24).

章节与相邻小节共享 PDF 页面;标题之前/之后的文本属于相邻小节。