Knobwerk

← 検索に戻る

9.5 MICRO TIMING MENU

9. THE SEQUENCER > 9.5 MICRO TIMING MENU · PDF p. 40 · OS 1.40A

# 9.5 MICRO TIMING MENU

9. THE SEQUENCER
and the [TRIG] keys where the generated trigs are placed will also be blue. Any trigs placed on the se­
quencer before activating the Euclidean mode will be hidden and inactive while in this mode, but they’ll
reappear when you turn the mode off again. If you want to convert an Euclidean sequence into regular
sequencer trigs, just press and hold [FUNC] while turning the Euclidean mode off. Any earlier placed trigs,
while not in Euclidean mode, will be removed. While in Euclidean mode, it is not possible to add note trigs
manually to the sequencer. However, you can still do parameter locking on the already generated trigs.
Press [TRIG PARAMETERS] twice to open the EUCLIDEAN SEQUENCER menu.
PL1 Pulse generator 1 sets the number of pulses (trigs) placed on the sequencer by this generator.
PL2 Pulse generator 2 sets the number of pulses (trigs) placed on the sequencer by this generator.
LEN Track length sets how many steps the track will have. This parameter is only available in PER
TRACK mode. For more information, please see “9.9 SCALE MENU” on page 42.
EUC Euclidean mode switches the Euclidean sequencer mode on/off.
R01 Rotation generator 1 rotates the trigs placed by generator 1 forward or backwards on the track.
R02 Rotation generator 2 rotates the trigs placed by generator 2 forward or backwards on the track.
TRO Track rotation rotates the trigs placed by both generator 1 and generator 2 forward or backwards
on the track.
OP Boolean operator lets you add or subtract the trigs generated from the two pulse generators in
different ways based on mathematical logical expressions.
OR all trigs from both generator 1 or 2 are placed on the track.
XOR trigs from both generator 1 or 2 are placed on the track unless they are added to the same
sequencer step.
AND only trigs added to the same sequencer step by generator 1 and 2 are placed on the track
SUB trigs from generator 1 are placed on the track unless generator 2 adds a trig on the same step
as generator 1.
9.5 MICRO TIMING MENU
Here you can add micro timing to a note trig, moving it ahead or behind the beat. Micro timing can be cus­
tomized on any of the sequencer steps on both audio and MIDI tracks. In GRID RECORDING mode, press
and hold one or several [TRIG] keys and then press [LEFT]/[RIGHT] to access the pop-up Micro timing
menu that shows the time offset for the chosen sequencer step(s) on the active track. Then press [LEFT]/
[RIGHT keys to adjust the time offset. To exit the micro timing menu, release the [TRIG] key(s). The micro
timing settings are stored in the active pattern
9.6 RETRIG MENU
Retrigs can be customized on any of the sequencer steps on the audio tracks (the retrig function is not
available on the MIDI tracks). In GRID RECORDING mode, press and hold one or several [TRIG] keys and
then press [UP]/[DOWN] to access the pop-up Retrig menu that shows the retrig actions for the chosen

チャンクは隣接セクションとページを共有します。見出し前後のテキストは隣のセクションのものです。