13.6 SAMPLES MENU
13. SAMPLING > 13.6 SAMPLES MENU · PDF 第 70–75 · OS 1.15A
# 13.6 SAMPLES MENU 13. SAMPLING 3. Press [RIGHT], to open the SAMPLE ACTION menu and then select LOAD TO TRK and press [YES] to load the sample to the active track. For more information, please see “13.6 SAMPLES MENU” on page 70. 13.4 SAMPLE PLAYBACK Once the sample is assigned to a track, it can be triggered either by the sequencer or manually by pressing a [TRIG] key. You also have the ability to set the samples play mode and edit what portion of the sample is played. 1. Press [SRC] to access the SOURCE page. 2. Set the TUNE of the sample. 3. Set the PLAY MODE behavior of the sample. • REVERSE The sample will be played back in reverse once every time it is trigged. • REVERSE LOOP The sample will loop continuously in reverse between Loop Position and Length. How long it will loop for is set with the LEN parameter on the TRIG page. The loop time is also con strained by the AMP page envelope parameter settings HLD and DEC. • FORWARD LOOP The sample will start from the start position and then loop continuously between Loop Position and Length. How long it will loop for is set with the LEN parameter on the TRIG page. The loop time is also constrained by the AMP page envelope parameters HLD and DEC. • FORWARD The sample will be played back once every time it is trigged. 4. Use DATA ENTRY knobs E, F, and G to set the STRT, LEN, and LOOP parameters which define what portion of the sample is played. Press [SRC] twice to access SRC page 2, in order to more easily see these settings using the sample waveform. • STRT Start sets the start position for the playback of the sample. • LEN Length sets the length of the playback of the sample. Start + Length effectively defines the end point of the portion of the sample that is played. • LOOP Loop Position sets the position in the sample to where playback will return after reaching the Length Position (defined by STRT + LEN) if PLAY MODE is set to FORWARD LOOP or REVERSE LOOP. The sample then loops between the end of LEN, and LOOP. For more information, please see “11.4 SRC PAGE” on page 55. 13.6 SAMPLES MENU Press [FUNC] + [SAMPLING] to open the SAMPLES menu. Use the [UP]/[DOWN] keys to select if you want to view the +Drive or the RAM storage. Press [YES] to open the selected storage space. Here you can manage your samples. Initially, here are two directories FACTORY and INCOMING. A wide array of factory samples are available in the write protected FACTORY directory. The INCOMING directory 13. SAMPLING is the default destination for samples sent to the Digitakt II +Drive storage via a SDS transfer software. A third directory, RECORDED will appear once you have done the first sampling on the device and will contain the samples you create when you sample with the Digitakt II. Use the [UP]/[DOWN] keys to highlight a directory, and then press [YES] to open it. To exit a directory and back one step up in the directory hierarchy, press [NO]. Pressing and holding [NO] takes you to the top level of the SAMPLES menu. When browsing a directory in the +Drive, a sample assigned to one of the 1016 sample slots of the active project will have its slot number shown as seen below. 13.6.1 LOADING A SAMPLE You can load one or several samples to the RAM memory of the active project. 1. Press [FUNC] + [SAMPLING] to open the SAMPLES menu, and then use the [UP]/[DOWN] keys to select +DRIVE. Press [YES] to open the +Drive storage. 2. Open the FACTORY directory, and navigate to the samples you want to load. 3. Highlight the samples, and then press [YES] to select them. Press [YES] on a selected sample to deselect it. Any sample can be previewed, played back by the voice of the active track (make sure to select an audio track). Highlight the sample and then press [FUNC] + [YES]. Approximately, ten seconds of the sample can be previewed. 4. Press [RIGHT] to open the SAMPLE ACTION menu. 5. Select LOAD TO PROJECT and press [YES]. The samples you selected (ticked) will now appear in the first available empty slots out of the 1016 sample slots of the active project. To view the samples currently in the RAM storage of the active project, press [FUNC] + [SAMPLING] to open the SAMPLES menu, and then use [UP]/[DOWN] to select the PROJECT RAM. Press [YES] to open the RAM storage. If you instead want to load the samples to a specific RAM bank, press [FUNC] + [YES] and then use [LEFT]/[RIGHT] or LEVEL/DATA or [TRIG 9–16] to select RAM bank. 13. SAMPLING On this screen, the 1016 samples may be unloaded individually or collectively to empty the slots. 13.6.2 UNLOADING A SAMPLE You can unload one or several samples from the RAM memory of the active project. 1. Press [FUNC] + [SAMPLING] to open the SAMPLES menu, and then use the [UP]/[DOWN] keys to select the PROJECT RAM. Press [YES] to open the projects RAM storage. 1. Scroll the list using [UP]/[DOWN] or the LEVEL/DATA knob. 2. Highlight the samples, and then press [YES] to select the samples, or bring up the SAMPLE AC TION menu by pressing [RIGHT] and choose SELECT ALL. 3. Press [YES] and then select UNLOAD, and then press [YES] again to empty the slots of the select ed samples. 13.6.3 REPLACING A SAMPLE You can replace a sample in the RAM memory of the active project. 1. Highlight the slot containing the sample you wish to replace, and then (without selecting any sam ples) press [RIGHT] to open the SAMPLE ACTION menu, and select REPLACE, and then press [YES] again. 2. Browse the directories of the +Drive, locate the desired sample and press [YES] to place it in the previously highlighted sample slot. If you wish to go back to browsing the +Drive storage directories, press [NO] to go back to the SAM PLES menu, and then use the [UP]/[DOWN] keys to select +DRIVE. Press [YES] to open the +Drive storage. 13.6.4 RENAMING A SAMPLE You can also rename a sample. 1. Navigate to the directory that contains samples you want to rename. 2. Highlight the sample you want to rename, and then press [YES] to select it. 3. Press [RIGHT] to open sample action menu, and then Select RENAME and press [YES]. 4. Use the NAMING screen to rename the sample and then press [YES]. 13.6.5 MOVING A SAMPLE You can move one or several samples from one directory to another. 1. Navigate to the directory that contains samples you want to move. 2. Highlight the samples you want to move, and then press [YES] to select them. 3. Press [RIGHT] to open the SAMPLE ACTION menu. 13. SAMPLING 4. Select MOVE SELECTED and press [YES]. 5. Navigate to the directory to where you want to move the samples. 6. Press [RIGHT] to open the SAMPLE ACTION menu and then highlight MOVE HERE. 7. Press [YES] to move the samples. 13.6.6 REMOVING UNUSED SAMPLES FROM RAM You can use this feature to remove all samples that are not used in any pattern in the project from the RAM memory. The samples are not removed from the +Drive. 1. Press [FUNC] + [SAMPLING] to open the SAMPLES menu, and then use the [UP]/[DOWN] keys to select PROJECT RAM. Press [YES] to open the RAM memory. 2. Press [RIGHT] and the SAMPLE ACTION menu will appear. Select SELECT UNUSED, and then press [YES]. 3. Select UNLOAD. A warning popup will appear asking “UNLOAD X SAMPLES? CONFIRM? Y/N”. Press [YES] to remove all unused samples. 13.6.7 TRANSFERRING SAMPLES FROM A COMPUTER TO DIGITAKT II 1. Connect Digitakt II to the computer via USB. 2. Open the Elektron Transfer software (Available on the Elektron website) on your computer. 3. On the Transfer CONNECTIONS page, set the MIDI IN and OUT ports to your Digitakt II. 4. In Transfer, click the EXPLORE tab to open the EXPLORE page. 5. On the top right side, in the drop-down menu, select “Samples”. 6. On the top left side in the drop-down menu, make sure “My Computer” is selected. 7. Under “My Computer” navigate to the files or folders you want to transfer. 8. Drag and drop the files or folders to your preferred location on your device. Transfer automatically converts all audio files to 16 bit, 48 kHz audio files, the Digitakt II native audio format. Both mono and stereo files are supported To use the samples, they need to be loaded to the active project. For more information, please see “13.6.1 LOADING A SAMPLE” on page 71. 13.6.8 CREATING A NEW DESTINATION DIRECTORY The Digitakt II still supports receiving of samples via MIDI Sample Dump Standard (SDS) and Extended SDS. You need to enable SDS Handshake in order to secure the transmission over fast interfaces like USB MIDI. You also have to enable the transmission of the Extended SDS header if you want the sample name to be sent to the Digitakt II. This procedure is only for when you use a SDS transfer software tool. If you use Elektron Transfer you can create a new destination directory in the Digitakt II directly from Transfer. Press [FUNC] + [SAMPLING] to open the SAMPLES menu, and then use the [UP]/[DOWN] keys to select the +Drive. Press [YES] to open the +Drive storage. Press [RIGHT] and select CREATE DIR to create a new directory by pressing [YES]. A naming screen will appear. Give your new destination direc tory an appropriate name. Press [YES] to open the new directory. In the initially empty directory, press [RIGHT] to open the SAMPLE ACTION menu. Highlight UPLOAD HERE and press [YES]. 13.6.9 TRANSFERRING SAMPLES FROM DIGITAKT II TO A COMPUTER 1. Connect Digitakt II to the computer via USB. 2. Open the Elektron Transfer software (Available on the Elektron website) on your computer. 3. On the Transfer CONNECTIONS page, set the MIDI IN and MIDI OUT ports to your Digitakt II. 4. In Transfer, click EXPLORE to open the EXPLORE page. 13. SAMPLING 5. On the EXPLORE page on the right side under DIGITAKT II, navigate to the samples you want to transfer 6. Drag and drop the samples to your preferred folder under MY COMPUTER. • Make sure you have the latest version of the Elektron Transfer software installed on your computer. You can download the free Transfer software and the Transfer User Manual from the Support section of the Elektron website. • If MIDI+USB is selected in the INPUT FROM and/or OUTPUT TO settings on the MIDI PORT CONFIG menu, MIDI data transfers will limit the USB speed. When sending or receiving large chunks of data, make sure you use the USB setting. • Sequencer playback stops when you transfer files to the Digitakt II. 14. SETTINGS MENU 14. SETTINGS MENU The SETTINGS menu offers settings that affect Digitakt II and can also be used to manage Projects. Press [SETTINGS] to access the SETTINGS menu. Scroll the list by using [UP]/[DOWN] or the LEVEL/ DATA knob. Open a highlighted menu by pressing [YES]. 14.1 PROJECT 14.1.1 LOAD PROJECT Load Project opens a project selection screen where you can choose a project to load. If you wish to create a new project, select CREATE NEW at the very bottom of the list. The new project will be a blank slate. If you load a new project it will replace the active project. Be sure to save your active project before you load another project. 14.1.2 SAVE PROJECT AS Save Project opens a project selection screen where you choose a slot to save the active project to. You can also press [FUNC] + [SETTINGS] to save and overwrite the current project. 14.1.3 MANAGE PROJECTS Manage Projects launches the PROJECT MANAGER menu. Selecting a project in this menu and pressing the [RIGHT] arrow key will bring up a list of commands. • CLEAR Resets the project slot to a clean state. • DELETE Removes the project from the slot. • RENAME Opens a NAMING screen where you can rename the project file. • LOAD FROM Loads the selected project. This will replace the active project! • SAVE TO Saves the active project to the selected slot. • TOGGLE Toggles write protection on or off. Write protected projects cannot be overwritten, re named or erased. A lock symbols in front of the project name shows that the project is write protected. • INIT NEW Initializes an empty file slot with a clean project. This option is only available for empty project slots. • PURGE ALL Purges (removes) all presets from the pool and all samples that are not used in any pat tern in the project from the RAM memory. The presets and samples are not removed from the +Drive library. This option is only available when you select the currently loaded project.
章节与相邻小节共享 PDF 页面;标题之前/之后的文本属于相邻小节。